Output
Output power capacity
18.0 KWatts / 20.0 kVA

Max Configurable Power (Watts)
18.0 KWatts / 20.0 kVA

Nominal Output Voltage
400V 3PH

Output Voltage Note
Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage

Efficiency at Full Load
91.4 %

Output Voltage Distortion
Less than 2%

Output Frequency (sync to mains)
50/60 Hz +/- 3 Hz user adjustable +/- 0.1

Output Frequency (not synced)
50Hz +/- 0.1% for 50Hz nominal

Other Output Voltages
380, 415

Load Crest Factor
2.5 : 1

Topology
Double Conversion Online

Waveform type
Sine wave

Overload Operation
10 minutes @ 125% and 60 seconds @ 150%

Maximum Output Current
190

Output Connections
(1) Hard Wire 4-wire (3PH + G) (Battery Backup)
Output Voltage THD
< 1% linear load and < 2.5% nonlinear load Output Voltage Tolerance +/-1% static and +/- 5% at 100% load step Bypass Built-in Maintenance Bypass, Built-in Static Bypass, Optional External Bypass Input Nominal Input Voltage 400V 3PH Input frequency 45 – 65 Hz Input Connections Hard Wire 4-wire (3PH + G), Hard Wire 4-wire (3PH + N) Input voltage range for main operations 323 – 437 (380V), 340 – 460 (400V), 353 – 477 (415V)V Input voltage adjustable range for mains operation 250 – 470V Efficiency at Full Load 91.4 % Input Total Harmonic Distortion Less than 3% for full load Type of Input Protection Required 3-pole breaker Other Input Voltages 380, 415 Maximum Short Circuit Withstand (Icw) 20.0kAmps Maximum Input Current 33.0A Input Power Factor at Full Load 1.0 Batteries & Runtime Battery type VRLA Typical recharge time 10hour(s) Nominal Battery Voltage 432V Expected Battery Life (years) 8 – 10 Replacement battery cartridge note Estimated runtimes only. Battery Volt-Amp-Hour Capacity 9850 Runtime View Runtime Graph View Runtime Chart Communications & Management Pre-Installed SmartSlot™ Cards AP9635 Control panel Multi-function LCD status and control console Emergency Power Off (EPO) Yes Available SmartSlot™ Interface Quantity 2 Physical Maximum Height 1900mm , 190.0cm Maximum Width 1110mm , 111.0cm Maximum Depth 855mm , 85.5cm Net Weight 958.0kg Shipping weight 978.0kg Shipping Height 2030mm , 203.0cm Shipping Width 1130mm , 113.0cm Shipping Depth 960mm , 96.0cm Environmental Operating Environment 0 – 40 °C Operating Relative Humidity 0 – 95 % Operating Elevation 0-999.9meters Storage Temperature -20 – 45 °C Storage Relative Humidity 0 – 95 % Storage Elevation 0-12000meters Audible noise at 1 meter from surface of unit 55.5dBA Protection Class IP20 Conformance Approvals CE, EN/IEC 62040-3, IEC 62040-1-2, IEC 62040-2, ISO 9001, TUV, VDE Standard warranty 1 year on-site repair or replace with factory authorized Start-UP, 1 year (parts only) General Max Bypass Input Current 29.0A