Home UPS MGE Galaxy 5500 20kVA 400V Single UPS, Start-up 5×8

MGE Galaxy 5500 20kVA 400V Single UPS, Start-up 5×8

MGE Galaxy 5500 20kVA 400V Single UPS, Start-up 5×8

Category:

Description


Output
Output power capacity
18.0 KWatts / 20.0 kVA

Max Configurable Power (Watts)
18.0 KWatts / 20.0 kVA

Nominal Output Voltage
400V 3PH

Output Voltage Note
Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage

Output Voltage Distortion
Less than 2%

Output Frequency (sync to mains)
50/60 Hz +/- 3 Hz user adjustable +/- 0.1

Output Frequency (not synced)
50Hz +/- 0.1% for 50Hz nominal

Other Output Voltages
380, 415

Load Crest Factor
2.5 : 1

Topology
Double Conversion Online

Waveform type
Sine wave

Overload Operation
10 minutes @ 125% and 60 seconds @ 150%

Maximum Output Current
190

Output Connections
(1) Hard Wire 4-wire (3PH + G) (Battery Backup)
Output Voltage THD
< 1% linear load and < 2.5% nonlinear load Output Voltage Tolerance +/-1% static and +/- 5% at 100% load step Bypass Built-in Maintenance Bypass, Built-in Static Bypass, Optional External Bypass Input Nominal Input Voltage 400V 3PH Input frequency 45 – 65 Hz Input Connections Hard Wire 4-wire (3PH + G), Hard Wire 4-wire (3PH + N) Input voltage range for main operations 323 – 437 (380V), 340 – 460 (400V), 353 – 477 (415V)V Input Total Harmonic Distortion Less than 5% for full load Type of Input Protection Required gL fuse Other Input Voltages 380, 415 Maximum Short Circuit Withstand (Icw) 20.0kAmps Maximum Input Current 42.0A Input Power Factor at Full Load 1.0 Batteries & Runtime Battery type No internal battery – uses external battery system Typical recharge time 10hour(s) Nominal Battery Voltage 432V Expected Battery Life (years) 8 – 10 Extended Run Options MGE-Galaxy-5500-20kVA-400V-Single-UPS-Start-up-5×8 End of Discharge Battery Voltage +/-154 V Overload Operation 60 seconds @ 120% and 30 seconds @ 145% Efficiency View Efficiency Graph Communications & Management Pre-Installed SmartSlot™ Cards AP9635 Control panel Multi-function LCD status and control console Emergency Power Off (EPO) Yes Available SmartSlot™ Interface Quantity 2 Physical Maximum Height 1900mm , 190.0cm Maximum Width 712mm , 71.2cm Maximum Depth 855mm , 85.5cm Net Weight 400.0kg Shipping weight 420.0kg Shipping Height 2030mm , 203.0cm Shipping Width 980mm , 98.0cm Shipping Depth 960mm , 96.0cm Environmental Operating Environment 0 – 40 °C Operating Relative Humidity 0 – 95 % Operating Elevation 0-999.9meters Storage Temperature -20 – 45 °C Storage Relative Humidity 0 – 95 % Storage Elevation 0-12000meters Audible noise at 1 meter from surface of unit 55.5dBA Protection Class IP20 Conformance Approvals CE, EN/IEC 62040-3, IEC 62040-1-2, IEC 62040-2, ISO 9001, TUV, VDE Standard warranty 1 year on-site repair or replace with factory authorized Start-UP, 1 year (parts only) Sustainable Offer Status Battery Directive Compliant Battery Notes ts_Battery_Notes General Max Bypass Input Current 29.0A

Reviews

There are no reviews yet.

Be the first to review “MGE Galaxy 5500 20kVA 400V Single UPS, Start-up 5×8”

Your email address will not be published.